| Size |
4.6" H x 2.4" W x 1.2" D (118 x 60 x 30 mm) |
| Weight |
8.29 oz. (235 g.) |
| Sensor |
Photoionization sensor with 10.6 eV (standard) or 9.8 eV2,3 (optional) lamp. Response time (T90) < 15 sec. (Isobutene). Field-replaceable sensor. Easy access to lamp for cleaning |
| Detectable Gases |
A wide variety of ionizable chemicals using 190 built-in and over 300 published correction factors |
| Battery |
Rechargeable Lithium-ion battery |
| - Operating time: > 12 hours (normal operation) |
| - Recharge time: < 4 hours through charging cradle |
| Display |
Graphical LCD display with white LED backlighting (activated when monitor is in alarm or with a button press) |
| Display Readout |
- Real-time reading of VOC concentrations in parts per million or mg/m3; battery status; data logging on/off; wireless on/off and reception quality |
| - STEL, TWA, and peak values |
| - Calibration and measurement gases; correction factors |
| Keypad |
2 buttons for operation and programming |
| Sampling |
Internal fan |
| Calibration |
Automatic with AutoRAE 2 Test and Calibration Station2 or manual |
| Alarm Modes |
Wireless remote alarm notification1,2; audible (95 dB @ 30 cm), vibration, visible alarm (flashing bright red LEDs), and on-screen indication of alarm conditions |
| - High alarm: 3 beeps and flashes per second |
| - Low alarm: 2 beeps and flashes per second |
| - STEL and TWA: 1 beep and flash per second |
| - Additional diagnostic alarm and display message for low battery and fan stall |
| Datalogging |
- Continuous datalogging3 with a three-month capacity (at one-minute intervals) |
| - User-configurable datalogging interval (from 1 to 3,600 seconds) |
| Communication and Data Download |
- Data download and instrument set-up on PC via charging and PC comm. cradle |
| - Data download via AutoRAE 2 Automated Test and Calibration Station2 |
| - Wireless data and status transmission1,2 via built-in RF modem (optional) |
| Wireless Network |
RAE Systems Dedicated Wireless Network |
| Wireless Frequency1,2 |
ISM license-free bands |
| Wireless Range1,2 (Typical) |
300 feet (100 meters) |
| Operating Temperature |
-4° to 131°F (-20° to 55°C) |
| Humidity |
0% to 95% relative humidity (non-condensing) |
| Dust and Water Resistance |
IP-54 rating for dust and water ingress protection (validated by an independent test laboratory) |
| Hazardous Location Approvals |
US and Canada: Class I, Division 1, Groups A, B, C and D. T-code T4. Class I, Zone 0 A/Exia IIC T4 |
| Europe: ATEX: II 1G, Ex ia IIC Ga T4. IECEx: Ex ia IIC Ga T4 |
| China: Ex ia IIC T4 |
| CE Compliance European Conformity) |
EMC directive: 2004/108/EC. R&TTE directive: 1999/5/EC. ATEX directive: 94/9/EC |